XtroLiner Underfloor PIR offers insulation performance with a thermal conductivity of 0.021 W/mK. The floor in any building is an area of considerable downward heat loss when not properly insulated.
XtroLiner Underfloor will significantly improve the U-Value of new and existing floors. It is lightweight and combines high compressive strength with low thermal conductivity, providing a solution for floor insulation.
* The reference to superior performance relates to the product or ranges thermal conductivity or fire performance or a combination of both, when compared to our Thin-R range.
* The reference to superior performance relates to the products of ranges * The reference to superior performance relates to the product or ranges thermal conductivity or fire performance or a combination of both, when compared to our Thin-R range.
Thickness
50mm, 60mm, 75mm, 80mm, 100mm, 120mm
Inner facing
textured Foil Facing
Outer facing
textured Foil Facing
Thermal Conductivity
0.021 (W/mK)
Unit of Measurement
mm
Compressive Strength
CS (10\Y) 150
Size/Dimensions
2400 X 1200mm
Reaction to Fire
Euroclass C s2 d0
Installation guidelines
Please see marketing materials
EPD
An Environmental Product Declaration (EPD), certified by IGBC is available for this product. Please contact technical support for further details
Typical U-Values
Table 1 U-Value calculations to EN ISO 6946:2017 XO/UF Insulation for Ground Supported slab
Thickness
0.30
0.40
0.50
0.60
0.70
0.80
75
0.17
0.19
0.20
0.20
0.21
0.21
80
0.17
0.18
0.19
0.19
0.20
0.20
100
0.14
0.15
0.16
0.16
0.17
0.17
120
0.12
0.13
0.14
0.14
0.14
0.14
150
0.11
0.11
0.12
0.12
0.12
0.12
65mm screed
Separating layer polythene sheet
XO/UF with perimeter strip
DPM 1200 gauge polythene or radon barrier
Concrete slab
Table 2 U-Value calculations to EN ISO 6946:2017 XO/UF Beam & Block Suspended Floor
Thickness
0.30
0.40
0.50
0.60
0.70
0.80
75
0.19
0.20
0.20
0.21
0.21
0.21
80
0.18
0.19
0.19
0.20
0.20
0.20
100
0.15
0.16
0.16
0.17
0.17
0.17
120
0.13
0.14
0.14
0.14
0.14
0.15
150
0.11
0.12
0.12
0.12
0.12
0.12
65mm screed
Separating layer polythene sheet
XO/UF with perimeter strip
Beam and block
Table 3 U-Value calculations to EN ISO 6946:2017 for IRL XO/UF Suspended Hollow Core floor